BetaIT-Hub is in early access — your feedback helps us improve. Use the chat or email [email protected]

News Vulnerability
VulnerabilityCISA·7d ago

Rockwell Automation 1718-AENTR/1719-AENTR

p a href= https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-202-08.json strong View CSAF /strong /a /p h2 Summary /h2 p strong Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. /strong /p p The following versions of Rockwell Automation 1718-AENTR/1719-AENTR are affected: /p ul li 1718/ 1719 Ex I/O 3.011 nbsp; /li /ul div class= csaf-table table class= tablesaw tablesaw-stack data-tablesaw-mode= stack data-tablesaw-minimap thead tr th role= columnheader data-tablesaw-priority= persist CVSS /th th role= columnheader Vendor /th th role= columnheader Equipment /th th role= columnheader Vulnerabilities /th /tr /thead tbody tr td v3 7.5 /td td Rockwell Automation /td td Rockwell Automation 1718-AENTR/1719-AENTR /td td Allocation of Resources Without Limits or Throttling /td /tr /tbody /table /div h3 Background /h3 ul li strong Critical Infrastructure Sectors: /strong Critical Manufacturing /li li strong Countries/Areas Deployed: /strong Worldwide /li li strong Company Headquarters Location: /strong United States /li /ul hr h2 Vulnerabilities /h2 div class= csaf-accordion p a class= csaf-accordion-toggle-all href= # Expand All + /a /p div class= csaf-accordion-item h3 a class= csaf-accordion-toggle href= # CVE-2026-9140 /a /h3 div class= csaf-accordion-content p A denial-of-service security issue exists in the 1719-AENTR. The security issue stems from improper handling of a UDP unicast network storm, which causes the device to become overloaded and lose communication. A power cycle is required to recover. /p p a href= https://www.cve.org/CVERecord?id=CVE-2026-9140 View CVE Details /a /p hr h4 Affected Products /h4 h5 Rockwell Automation 1718-AENTR/1719-AENTR /h5 div class= ics-vendor-version-status div class= ics-vendor strong Vendor: /strong br Rockwell Automation /div div class= ics-version strong Product Version: /strong br Rockwell Automation 1718/ 1719 Ex I/O: 3.011 /div div class= ics-status strong Product Status: /strong br known_affected /div /div div class= ics-remediations h6 Remediations /h6 p strong Vendor fix /strong br Rockwell Automation recommends users to upgrade to 1718/ 1719 Ex I/O version 3.012 or later. /p p strong Mitigation /strong br Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight). br a href= https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight /a /p p strong Mitigation /strong br For more information, see Rockwell Automation Security Advisories: https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html. br a href= https://www.rockwellautomation.com/en-

Sign in to read the full article

Create a free account to access all news, downloads, and community features

Originally published by CISA

Source: https://www.cisa.gov/news-events/ics-advisories/icsa-26-202-08

This article is shared for informational purposes. All rights belong to the original author and publisher. If you are the copyright holder and would like this content removed, please contact us.

Shared on IT-Hub by admin